CUSTOM MARINE SERVICES

Electrical Marine Parts For Boats & Yachts!

Specializing In  Circuit Breakers & Transfer Switches

             The Quick Source ... 

Distributor... Serving The Industry Since 1973! 

Klixon 6TC Aircraft Circuit Breakers

*
Klixon

Aircraft Circuit

Breakers

 

 
 
 
 
 
 


 
 
Voltage Drop
 
Amp Rating
Max. Voltage Drop*
2
0.70
0.50
3
0.40
4
0.37
5
0.35
0.192
10
0.176
15
0.176
20
0.176
* Maximum voltage drop at nominal rated current.


 
 
* * *


 2 to 20 amp, 3 phase

Features and Overview
 
Miniature size
Light weight
Trip–free design
MIL-C-5809 qualified
Current rating: 2 to 20 amps
High vibration resistance
High interrupting capacity
Protective terminal barriers between each phase
 
Vibration pads improve mounting stability
One phase trips all
Options include: longer push buttons, dust boot (part #14500-1 fits 15/32 bushing, part #14500-5 fits 7/16 bushing)
Typical use: Military and commercial aircraft
* * *


Picture of 6TC

 

9TC


Klixon 6TC series circuit breakers provide ambient compensated circuit protection in a lightweight, miniature package size. The three–phase integrally linked design provides over current protection in the event of simultaneous or unbalanced overloads, including short circuit conditions.

Coordination
The 6TC series is compatible with the single–phase 2TC and 3TC. The 6TC is available in ratings from 2 to 20 amps, with military and various commercial approvals on most styles.

Ambient Temperature Compensation
The 6TC serves as an ambient compensated circuit breaker. This permits system designers to specify smaller gauge wire where the circuit breaker and wiring are exposed to different ambient temperatures.

Trip–Free
The complete line of TC series circuit breakers is trip–free. The circuit breaker cannot be maintained closed during an overload even with the actuator button held closed.

High Short Circuit Capacity
For its miniature size, the 6TC series offers unusually high current interrupting capacity. Overloads up to 2,000 amps at 120 VAC, 400 Hz can be safely interrupted without affecting calibration or operating performance in the standard 6TC.
 
Performance Characteristics
 
Vibration
10G minimum, 50–500 Hz (other vibration levels available)
Mechanical Shock
50G
Acceleration
10G
Weight
65 gram maximum (6TC14)
Interrupt Current
2–20 amps: 2,000 amps at 120 VAC, 400 Hz
Endurance
2,500 cycles: 120 VAC, 400 Hz inductive
5,000 cycles: 120 VAC, 400 Hz resistive
5,000 cycles: Mechanical, no load
Ambient Temperature Compensation
-54°C to 121°C
Especially suited for applications where ambient temperature exceeds the 71°C (160°F) maximum of non–ambient compensated thermal circuit breakers. However, care should be taken to understand the specification limits at elevated ambient temperatures.
 
Qualifications
 
European
European Standards
Most European Aircraft OEMs
Mil–spec
MS 14154 (our 6TC2 device)
MS 14154L (our 6TC37 device)
MS 14154V (our 6TC63 device)
USA
All U.S. Aircraft OEMs
Calibration Chart For a Standard Device
 
Temp.
Minimum Ultimate Trip
Maximum Ultimate Trip
Trip Time in seconds
200%
500%
1000%
25°C
110%
145%
4-20
0.40-2.00
0.10-0.53
-54°C
110%
165%
6-40
0.55-3.50
0.15-0.80
71°C
100%
145%
3-20
0.33-1.70
0.08-0.40
 
Trip Curve
 

Approximate Time-Current Curves
 
Drawings and Dimensions For Reference Only
 
6TC Diagram
 
Spec Sheets For Our Most Popular Devices
 
Spec sheets contain detailed drawings, amp ratings, characteristics, and more...
6TCX
Device Type
Spec Sheet
6TC2
- - -
Download spec sheet
6TC14
- - -
Download spec sheet
6TC37
- - -
Download spec sheet
6TC63
- - -
Download spec sheet

                                               

We Also Offer Other Quality Electrical  Products  by Quality  Manufacturers  For Aircraft - Marine - Motor Coach - RV's - Emergency & Specialty Vehicles

<---------   Previous Page

Services You Expect

Next Page   ---------->

  Contact CMS  |  Price & Del Ck  O/L Ordering | Policy  |  Privacy  Projects  Sitemap

Revised: 19-Mar-2007 13:46:07

Bookmark Custom Marine Services

Designed & Maintained By DLAN